State-of-the-Art Measurement Analysis Software, Training and Consulting Services
Celebrating over 28 YRS of Excellence and Innovation 1987-2015
    Google 
internet isgmax.com

 

 

 

Products Software IntervalMAX 2.0 Program Features Browse Screens

 

IntervalMAX Calibration Interval Analysis Software from Integrated Sciences Group  IntervalMAX 2.0 - Browse Screens

IntervalMAX Calibration Interval Analysis Software - Browse Models Screen

 

Browse Screen Features

The IntervalMAX database may be browsed to see the effects of an analysis, view service history data, implement Reliability Target changes, etc.  The Browse Screens are accessed from the Browse menu on the Main Screen.  Available Browse Screens include:
 

Browse Class Codes
Browse Subclasses
Browse Similar Equipment Groups
Browse Models

Browse Manufacturers
Browse Serial Numbers
Browse Cumulative History 

  

Each of these Screens contain activation buttons to access lower level Browse Screens. The features and functions of the various Browse Screens are described below.

 

Browse Models

The Browse Models Screen shown above displays virtually all that can be said about Manufacturer/Models that have been analyzed by IntervalMAX.  Manufacturer/Model Reliability Targets may be changed on the Browse Models Screen.  The Reliability Target for a specific Manufacturer/Model is changed via the following procedure:
 

  1. Click the row in the grid for the Manufacturer/Model that the item belongs to.

  2. Click the cell containing its Reliability Target.

  3. Type the desired Reliability Target in the cell. This must be a decimal number between zero and one.

 
When a new Model Level analysis is run, the Model Level interval will be computed using the new Reliability Target. Modifying a Model Level Reliability Target activates the Model Reliability Targets Screen where you have the option to apply a Model Level Default change to only new Serial Numbers, as they are added to the Model Number, or to apply the change to both new and existing Serial Numbers. In the latter case, you have the option to change the Reliability Targets for all items within the Manufacturer/Model or only those items currently set at the Model Level Default.

 

Browse Serial Numbers

If criticality, usage or other requirements dictate that a given instrument be calibrated more or less frequently than others, the control for meeting this requirement may be implemented in the form of an individual Reliability Target. Individual instrument Reliability Targets may be set on the Browse Serial Numbers Screen. 

  

Browse Class Codes and Subclasses

These Browse Screens show the current status of each Instrument Class or Subclass with respect to interval control variables.  The Reliability Target for an Instrument Class or Subclass may be changed regardless of whether an interval approval has taken place or not. However, the change will not be implemented for the current analysis results. It will come into effect in the next analysis run.  Instrument Classes and Subclasses can be created, updated or deleted with the Class Code Builder.

  

Browse Similar Equipment Groups

This Browse Screen shows the current status of each Group with respect to interval control variables.  The field Analysis Candidate deserves some comment, however. An Analysis Candidate is an Instrument Class, Similar Equipment Group or Manufacturer/Model that has accumulated sufficient data since its prior analysis to justify a new analysis.  The option to analyze only Analysis Candidates is provided on the Candidate Selection Pick List Screen.
 

Defining a Similar Equipment Group is advisable from the standpoint of accumulating sufficient data for interval analysis. Similar Equipment Groups can be created, updated or deleted with the Similar Equipment Group Builder. The Reliability Target for a Similar Equipment Group may be changed regardless of whether an interval approval has taken place or not. However, the change will not be implemented for the current analysis results. It will come into effect in the next analysis run.
 

Browse Manufacturers
The contents and usage of this screen is similar to the Browse Models Screen.

 
Browse Cumulative History 

When the Candidate Selection Pick List and the Data Filter Pick List Screens are used, IntervalMAX isolates a subset of its cumulative service history that corresponds to the pick list keys. All fields for each record of this subset can be viewed using the Browse Cumulative History Screen.

 

 